ROTOCON Model MC high current rotary contacts are an innovative new concept. Unlike conventional slip ring contacts, the MC uses Meridian Laboratory's proprietary sealed design. Arcing, "make and break" electrical contact, friction, and the resulting short operating life are all eliminated by using the MC. Welding, plating, and other high current applications benefit with longer product life and substantially reduced energy consumption. A typical slip ring contact can lose 40% of its electrical efficiency due to unavoidable wear -- while the MC continues working with greater than 95% efficiency! The MC's energy savings alone make it an excellent investment. The MC can operate continuously at the rated maximum current without auxillary cooling and is designed to handle 100% current overloads (with some heat generation). The surprisingly small size of the MC Series makes installation quick and easy. Tight seals and a corrosion proof housing provide a long service life with zero maintenance.


model mc

model mc diagram

Model No. Max. Amps A B C D Wt (lbs.)
MC-250 250 4.50 2.00 3/8-16 1.63 1.3
MC-500 500 5.25 2.31 9/16-12 2.00 2.3
MC-750 750 6.62 2.62 3/4-10 2.50 4
MC-1000 1000 8.62 3.62 1-8 3.00 15
MC-2000 2000 14.50 6.25 1 1/2-6 4.50 32

Note 1: Dimensions subject to change without notice. If precise dimensions are required, contact Meridian Laboratory.
Note 2: Higher current capacity designs are available.
Note 3: See the MXP Series for high power handling with multiple contacts.

{short description of image}
Features
  • Compact Size
  • 95% Energy Efficient
  • Zero Maintenance
  • Eliminates Arcing
  • Environmentally Sealed
  • Rugged Design
  • Continuous Duty Cycle Operation
  • Handles 100% Overloads
  • Free Air Cooling
  • Mount In Any End Of Shaft Orientation

Specifications
Mechanical

RPM: 0-1000 continuous.*
Mounting: Any end-of-shaft orientation is acceptable. One end of the MC must have a flexible link to the equipment. Rigid connection of both ends should be avoided.
Housing: Corrosion resistant stainless steel.
General: Permanently lubricated bearings at both ends.
Electrical

Voltage: Any voltage is acceptable with single contact MC.
Current: See table above.
Frequency: DC or AC.
Stationary Contact Resistance: One milliohm.
Rotating Contact Resistance: Same as stationary resistance, no change with RPM.
Environmental

Ambient Temperature: Not to exceed 160°F (70°C), assuming minimal heat flow through shaft and housing mounts. If machinery surfaces are hot, use insulated mounting systems.
Relative Humidity: No effect.

* Please contact Meridian Laboratory for precise ratings