Hazardous Location / Explosion Proof Slip Rings

ROTOCON HLMX Series

Hazardous Location Slip Rings, Explosion Proof Slip Rings
  • Hazloc Slip Ring, Hazardous Location Slip Ring, Explosion Proof Slip Ring
  • Hazardous Location Slip Rings, Explosion Proof Slip Rings
  • Hazloc / Hazardous Location Slip Rings; Explosion Proof Slip Rings
  • Slip Rings for Hazardous Locations

Explosion Proof Slip Rings for Hazardous Locations – Certified, Reliable, and Customizable

» Certified for Hazardous Locations – IEC Ex db IIC T6 Gb and ATEX Ex II 2 G compliance for safe use in explosive gas and vapor environments» High Performance – Supports 2 to 30 electrical channels, up to 3,000V, and speeds up to 500 RPM
» Flexible Mounting Options – End-of-shaft configuration available with or without a junction box to fit your application needs» Maintenance-Free, Arc-Free Design – Utilizes proven ROTOCON® brushless technology for reliable, long-lasting performance in critical environments

Meridian Laboratory’s HLMX series of Explosion Proof Slip Rings are engineered for safe and reliable operation in hazardous environments where flammable gases or vapors may be present. Certified to meet IEC Ex db IIC T6 Gb and ATEX Ex II 2 G standards, ROTOCON hazardous location slip rings are designed for use in demanding applications requiring robust explosion protection.

Our explosion-proof slip rings are designed for end-of-shaft mounting and are available with or without an integrated junction box, providing flexible installation options to suit your specific needs. The ROTOCON HLMX series can be configured with 2 to 30 electrical channels, supporting voltages up to 3,000V and rotation speeds up to 500 RPM.

Backed by Meridian Laboratory’s proven ROTOCON® brushless slip ring technology, our slip rings offer maintenance-free, arc-free performance, ensuring long-term durability and safety in ATEX/IECEx classified areas.

Why Choose ROTOCON? Request a ROTOCON quote

Each unit of the HLMX series is tested and certified by Labtest Certification Inc. to meet the following standards:

IEC Ex db IIC T6 Gb and/or ATEX Ex II 2 G.

  • “db” = flameproof enclosure: ensures any internal explosion will not ignite the external atmosphere.
  • “IIC” = covers the most dangerous gas groups (e.g., hydrogen, acetylene).
  • “T6” = limits surface temperature to ≤85°C, offering the highest level of protection within the temperature classification system, essential for preventing ignition in highly volatile gas environments.
  • “Gb” = high level of protection for Zone 1 use (an area where explosive gas atmospheres are likely during normal operation).
RPMUp to 500 RPM Continuous
MOUNTINGFlange mounting on rotor (standard)
HOUSING304 Stainless steel
OPERATIONCan be operated in any direction or orientation
MAINTENANCEFeatures permanently lubricated bearings, brush-free design requires no user maintenance
VOLTAGEStandard: Up to 600V AC/DC
MINIMUM INSULATION RESISTANCE>50MΩ @ 1kVDC
AMPERAGEUp to 16A Per Channel
DATA & SIGNAL TRANSMISSIONEthernet (10/100/1000Mbps), Etherlink, LAPPNET, Profinet, Profibus, ControlNet, DeviceNet, CAN-Bus, RS485, RS432, RS422, USB (1.0/2.0), Modbus, EtherCAT, CC-Link, coax, thermocouple (all types) and all other major communication protocols (With an appropriate number of circuits and cables)
STATIONARY CONTACT RESISTANCE<0.1mΩ
ROTATING CONTACT RESISTANCESame as stationary contact resistance (<0.1mΩ)
ELECTRICAL NOISE<0.01uV
OPERATIONIntrinsically immune to internal arcing
OPERATING TEMPERATURE-20°C to 50°C
IP RATINGAvailable up to IP66
GENERALUnaffected by saltwater environments, vibrations, and other liquids, gases, and mediums
ROTORFlying Leads or Junction Box
BODYFlying Leads or Ring Terminals (within housing)
FIBER TYPESSingle-mode E9/125μm
Multi-mode G50/125 μm
Multi-mode G62.5/125 μm
*Fiber protection available
CHANNELSStandard: 1, 2, 3-20 Channels
Custom: Up to 81 Channels
CONNECTOR TYPESC, LC, FC, ST, LSA, Molex/LC, LuxCis
POLISHUPC, APC, PC
DIGITAL DATA TRANSMISSIONUp to 40Gbits/s per channel
RPMUp to 3,000 RPM (Model specific)
TEMPERATURE-40F to 185F

Advantages

  • IECEx and ATEX Certified for Worldwide Use
  • Environmentally Sealed & Dust-Free
  • Brushless Slip Ring Technology for Superior Performance
  • 100% Maintenance-Free
  • Lossless Electrical Signals
  • Reliable, High Speed Ethernet & Data

Applications

  • Oil & Gas Exploration
  • Alcoholic Beverage Distilling & Bottling
  • Automated Paint Application
  • Pharmaceutical and Chemical Mixing
  • Mining Operations

Hazardous Location / Explosion Proof Slip Ring Models

ModelContactsMax Current/ContactVoltageData CapableBody LengthOverall LengthElectrical Terminations
HLMX-2218A600VYes8.85 [224.8]10.9 [278]Ring terminals, potted flying leads, or junction box.
HLMX-4418A600VYes8.85 [224.8]10.9 [278]Ring terminals, potted flying leads, or junction box.
HLMX-8818A600VYes8.85 [224.8]10.9 [278]Ring terminals, potted flying leads, or junction box.
HLMX-121218A600VYes11.20 [284.5]13.3 [337]Ring terminals, potted flying leads, or junction box.
HLMX-151510A600VYes11.20 [284.5]13.3 [337]Ring terminals, potted flying leads, or junction box.
HLMX-202010A600VYes13.95 [354.3]16.0 [704]Ring terminals, potted flying leads, or junction box.
HLMX-24245.5A600VYes15.60 [396.3]17.7 [450]Ring terminals, potted flying leads, or junction box.
Need a different arrangement? Not all models are listed, contact Meridian Laboratory for other models, and specific information.

HLMX Series Product Manual

HLMX Series Datasheet (without junction box)